Question of the Month: Can you apply a coating while the floor heating is on?

Heating season is in full swing, and many floors are now pleasantly warm. But how do our products perform when the underfloor heating is on?

That’s exactly what one user wanted to know from our OBTEGO AI this month:

“Can R-400 be applied to a concrete floor with underfloor heating set to 20 degrees?”

OBTEGO AI’s answer:

“Yes, OBTEGO R-400 can be applied to a concrete floor with a surface temperature of 20 °C; this falls within the recommended application temperature range of approximately 10 °C to 25 °C. Direct sunlight must be avoided during application. If necessary, turn off the underfloor heating and protect the floor from direct moisture until it has fully cured. Additionally, the floor must be dry, solid, clean, and absorbent.”

What’s the reasoning behind this?

The set temperature does not necessarily correspond to the surface temperature. The floor can be significantly warmer above the heating pipes. This shortens the application time, can impair the appearance, and cause bubbles due to rising air from the concrete.

Our Recommendation

Turn off the heating before application or turn it down significantly, and only gradually turn it back up after the material has fully cured. For details, see the technical data sheet; if you have any questions, our application engineering team will be happy to assist you.